Dampak Usia Pemakaian PMS terhadap Kenaikan Suhu dan Kinerja Peralatan pada Gardu Induk

  • Aulidina Dwi Nur Andriyanti Universitas Teknologi Surabaya
Keywords: Disconnecting switch, Age of use, Increasing temperature, Substation

Abstract

Electric power generation is an important factor in an electrical system. The electrical energy that been generated, it would be distributed to consumers, both medium voltage and low voltage consumers. Before being distributed, the energy would be directed to substations to be managed and regulated by being increased, decreased, or divided. In substations, there were several protective devices that had function to protect equipment in the event of a disturbance, one of these devices is the PMS or disconnecting switch. This busbar disconnecting switch or PMS secured the system by separating the system from disturbances detection in the busbar. As the other electrical equipment, protective devices that have been used for a long time, it would lead to malfunction and decreasing of work. Therefore, this study focused on the condition of PMS that has been used for a long time, so this case could affect its temperature and performance. The researchers used a field study method for solving the problem. The result of this research showed that the long-term use of PMS could have an impact on decreasing performance and indicate the presence of hotspots and contact resistance exceeding the applicable standards.

References

Andriyanti, A. D. N. (2025). Pengaruh Lama Pemakaian Minyak Shell Diala B Terhadap Kuat Tegangan Tembus. Jurnal Mosfet, 5(2), 147–158. https://doi.org/10.31850/jmosfet.v5i2.3892

Dimas Prenata, G., Harja, A., & Wardah, I. A. (2025). KLASIFIKASI SUHU PADA PERALATAN LISTRIK TEGANGAN TINGGI MENGGUNAKAN K-NEAREST NEIGHBOR. TESLA, 27. https://doi.org/10.24912/tesla

Hadi, V. (2022). STUDI ANALISA PENGUKURAN JARAK KELISTRIKAN GARDU INDUK 150 KV.

Jethro Varian, S., & Sulistyo, L. (2024). PEMELIHARAAN PEMISAH (PMS) 150 DI GARDU INDUK 150 KV WONOGIRI. Jurnal ELKON, 4(1), 2809–140.

Kusmayadi, A., Utomo, M. H. B., & Sitorus, F. (2015). PROSEDUR PENGECEKAN DAN PENANGANAN HOTSPOT PADA PMS GARDU INDUK 150 KV PEMATANGSIANTAR MENGGUNAKAN METODE THERMOVISION. Jurnal Ilmiah Penelitian Mahasiswa, 3(6).

Muliadi, Syukri, & Asyadi, T. M. (2022). Pengaruh Tingkat Kelembaban Terhadap Kinerja Pemisah (PMS) 150 kV Pada Gardu Induk. Jambura Journal of Electrical and Electronics Engineering, 4, 92–98.

Pahiyanti, N. G., Sukmajati, S., & Malik, A. (2021). Nilai Tahanan Kontak Pada PMS BAY Cengkareng Terhadap Rugi Daya Di Gardu Induk Duri Kosambi. SUTET, 11(2), 61–70. https://doi.org/10.33322/sutet.v11i2.1557

Putri Suhesya, A., Randa Cahyono, H., Permata Kasih, R., & Satria Pamungkas, Y. (2024). Kajian Literatur tentang Teknik Pengujian Tegangan Tinggi Impuls pada Sistem Distribusi Listrik. IJEERE: Indonesian Journal of Electrical Engineering and Renewable Energy, 4, 42–46. https://doi.org/10.57152/ijeere.v4i1

Rajagukguk, A. S. F., Pakiding, M., & Rumbayan, M. (2015). Kajian Perencanaan Kebutuhan dan Pemenuhan Energi Listrik di Kota Manado. E-Journal Teknik Elektro Dan Komputer, 1–12.

Rochman, W. K. J. (2024). Kelayakan Pemisah (Disconnect Switch) 500 Kv Berdasarkan Hasil Uji. Innovative, 4.

Rosihan, A. W., Supriyatna, & Sultan. (2022). Analisis Sistem Proteksi Rele Differensial Pada Busbar Di Gardu Induk 150 kV Paokmotong ARTICLE INFO ABSTRACT. Diektrika, 8(2), xx–xx. https://dielektrika.unram.ac.id

Siswanto, A., Alfian, R., & Subyanta, E. (2021). ANALISIS KINERJA PMS REL 2 BAY TRAFO 6 MENGGUNAKAN THERMOVISION METHODE DI GARDU INDUK SUNYARAGI. Foristek, 11(2). https://doi.org/10.54757/fs.v11i2.113

Yonatan Siallagan, J., & Tanjung, A. (2021). STUDI KEBUTUHAN PERENCANAAN PEMASANGAN BUSBAR PROTEKSI PADA GARDU INDUK DUMAI PT. PLN (PERSERO) UPT PEKANBARU. 15(2), 94–103.

Yusmartato, Parinduri, L., & Sudaryanto. (2017). Pembangunan Gardu Induk 150 KV di Desa Parbaba Dolok. Cetak) Journal of Electrical Technology, 2(3).

Published
2026-07-31
Section
Articles