Analisis Perbandingan Karakteristik Aliran Teradap Nilai Kekasaran Pipa Yang Berbeda
Abstract
Flow obstructions often occur in the flow that passes through a pipe installation. As a result, head loss and pressure drop occur which are influenced by fluid friction and changes in the flow pattern of a pipe. However, under certain conditions, frictional resistance is only influenced by fluid viscosity. The aim of this research is to analyze the characteristics of the flow of roughness values in PVC pipes and the flow of roughness values in PP-R pipes using experimental methods carried out in the laboratory. The data that has been collected analyzed using the Reynolds equation, Darcy equation and Bernoulli equation. The research results showed that the characteristic of PVC pipes with the largest froude number value which 0.315 and the smallest which 0.090 were subcritical flow. Meanwhile, the characteristic of the PP-R pipe with the largest froude number value which 0.297 and the smallest which 0.057 were also subcritical flow.
References
Aisyah, S., Effendi, Z., & Pratama, W. Y. (2021). Analisa Head Losses dengan Penerapan Simulasi pada Diameter Pipa dan Pengaruh Nilai Net Positive Suction Head terhadap Terbentuknya Kavitasi pada Pompa. Jurnal Keteknikan Pertanian, 9(1), 17-22
Alkindi, H., Santosa, H., & Sutoyo, E., (2023). Analisis Head Losses Pada Circulating Fluida Air Dalam Dua Jenis Pipa, 9(1), 51-56
Armaja, R. S., & Akbar, A. (2023). Analisa Head losses Aliran Laminar pada Instalasi Perpipaan Laboratorium FDM. Prosiding SEMNAS INOTEK (Seminar Nasional Inovasi Teknologi), 7(2), 772–779.
Chow, V. T. (1992). Hidrolika Saluran Terbuka (Open Chanel Hydraulics). Jakarta : Erlangga
Erizal, M. G. (2013). Buku Ajar Hidraulika. Bogor : Institut Pertanaian Bogor
Hutagalung, M., & Aritonang, J. W. W. (2023). Besarnya Head Losses Pada Aliran Perpipaan Dari Boiler Feed Water Pump Menuju Boiler Di PT. Z. JURNAL VOKASI TEKNIK (JUVOTEK), 1(3), 19-28
Mardini, Z. (2022). Pengaruh Losses / Pressure Drop Pada Sistem Perpipaan Header Pompa Dalam Menentukan Spesifikasi Pengadaan Pompa Distribusi. Jurnal Rekayasa, 11(2), 183 - 192.
Narding, Y. C., Kusuma, D., Saidatin, N., & Lillahulhaq, Z. (2021). Pengaruh Variasi Ukuran Pipa terhadap Head loss pada Instalasi Perpipaan di Desa Sumbermanggis. Senastitan, 1, 365-369
Rahayu, P., Putri, D. K., Rosalina, & Indriyani, N. (2021). Pengaruh Diameter Pipa Pada Aliran Fluida Terhadap Nilai Head Loss. JURNAL AGITASI, 2(1), 23-32
Rumaherang, E. J., Wattimena, W. M. E., Rawulun, S. M., & Noya, E. (2023). Studi Regim Aliran Fluida Dan Penentuan Head Loss Akibat Gesekan Pada Instalasi Perpipaan. ALE Proceeding, 6, 154-161.
Sudirman, S., & Harves, H. (2022). Analisa Headloss Aliran Fluida Pada Pipa Lurus Dengan Variasi Debit Aliran Dan Variasi Diameter Pipa. Jurnal Mekanova, 8(2), 165-173
Triatmodjo, B. (1996). Hidraulika I. Yogyakarta : Beta Offset.
White, M. F., & Hariandja, M. (1988). Mekanika Fluida (terjemahan). Jakarta : Erlangga.
Yahya, A. K., Rahayu, P., Ulia, H., & Maulana, A. Y. (2022). Analisa Head Loss Dan Kerja Pompa Dengan Variasi Perubahan Diameter Pada Sistem Pemipaan. SAINTI: Majalah Ilmiah Teknologi Industri, 19(2), 51-57
Zulkifli, R. (2012). Hukum Bernoulli dan penerapannya. Jakarta : Erlangga