PENGARUH UKURAN BUTIR AGREGAT KASAR TERHADAP KAPASITAS KUAT TEKAN DAN NILAI SLUMP BETON POROUS
Abstract
Porous concrete is an innovation and development solution for parking areas, yards and pedestrian areas, as a way to avoid standing water or even flooding. The purpose of this study was to determine the proportion of the optimum coarse aggregate mixture for porous concrete in terms of compressive strength and slump value. The research method used was experimental research conducted at the Laboratory of Structures and Materials, Muhammadiyah Parepare University. The results of this study can indicate that the optimum mixture proportions were obtained at aggregate variations of 0.5-1 cm. The compressive strength with an aggregate size of 0.5-1 cm is 6.13 MPa, an aggregate size of 1-2 cm is 5.47 MPa, while an aggregate size of 2-3 cm is 5.00 MPa. The slump value with an aggregate size of 0.5-1 cm is 196 mm, an aggregate size of 1-2 cm is 192 mm, while an aggregate size of 2-3 cm is 178 mm.
References
Elizondo-Martinez, E. J., Andres-Valeri, V. C., Rodriguez-Hernandez, J., & Castro-Fresno, D. (2019). “Proposal of a New Porous Concrete Dosage Methodology for Pavements,” Materials, Vol. 12, No. 19, hlm. 1-16.
https://doi.org/10.3390/ma12193100
Nurfaizatu, S., Agung, Z., & Riyanto, E. (2021). “Kajian Beton Porous Menggunakan Agregat 1-2 cm Dengan Pengisi Abu Batu,” Jurnal Surya Beton, Vol. 5, No. 2, hlm. 10–20.
http://jurnal.umpwr.ac.id/index.php/suryabeton
Purnamasari, E., & Handayani, F. (2020). “Beton Porous Dengan Menggunakan Agregat Lokal Di Kalimantan Selatan,” Jurnal Kacapuri, Vol. 3, No. 1, hlm. 139-149.
http://dx.doi.org/10.31602/jk.v3i1.3618
Badan Standar Nasional. (2011), ”Cara Uji Kuat Tekan Beton Dengan Benda Uji Silinder: SNI 1974:2011,” Jakarta: BSN
Badan Standar Nasional. (2008), “Cara Uji Slump Beton: SNI 1972:2008,” Jakarta: Departemen Pekerjaan Umum.
Ginting, A. (2015). “Perbandingan Kuat Tekan Dan Porositas Beton Porous Menggunakan Agregat Kasar Bergradasi Seragam Dengan Gradasi Menerus,” ReTII, hlm. 377–383.
Nasrul, Samsul, Gusneli Yanti, and Shanti Wahyuni Megasari. (2021). "Hubungan Kuat Tekan dan Kuat Lentur pada Beton Berpori," Jurnal Rekayasa Konstruksi Mekanika Sipil, Vol. 4, No. 1, hlm. 1-8.
https://doi.org/10.54367/jrkms.v4i1.1122
Khonado, M. F., Manalip, H., & Wallah, S. E. (2019). “Kuat Tekan Dan Permeabilitas Beton Porous Dengan Variasi Ukuran Agregat,” Jurnal Sipil Statik, Vol. 7, No. 3, hlm. 351–358.
https://doi.org/10.30601/jtsu.v8i1.2609
Desmaliana, Erma, et al. (2018). "Kajian eksperimental sifat mekanik beton porous dengan variasi faktor air semen," Jurnal Teknik Sipil, Vol. 15, No. 1, hlm. 19–29.
https://doi.org/10.24002/jts.v15i1.3147
Ridho, M. Tata, A. Nurdin, S. (2021). "Karakteristik Beton Berongga Ramah Lingkungan Dengan Material Lokal Kota Ternate," Journal of Science and Engineering, Vol. 4, No. 2, hlm. 151-157.
http://dx.doi.org/10.33387/josae.v4i2.4041
Mustakim, Hairil, Yanas. (2021). “Karakteristik Beton Menggunakan Agregat Kasar Sungai Karawa Kabupaten Pinrang,” Jurnal Karajata Engineering, Vol. 1, No. 1, hlm. 35-41.
https://doi.org/10.31850/karajata.v2i1
ACI, 2010. Report on Pervious Concrete ACI 522R-10. American Concrete Institute, Farmington Hills.